GSK591

Katalog-Nr.S8111 Charge:S811101

Drucken

Technische Daten

Formel

C22H28N4O2

Molekulargewicht 380.48 CAS-Nr. 1616391-87-7
Löslichkeit (25°C)* In vitro DMSO 76 mg/mL (199.74 mM)
Ethanol 76 mg/mL (199.74 mM)
Water Insoluble
In vivo (Lösungsmittel einzeln und der Reihe nach zum Produkt hinzufügen.)
Homogeneous suspension
CMC-NA
≥5mg/ml Taking the 1 mL working solution as an example, add 5 mg of this product to 1 ml of CMC-Na solution, mix evenly to obtain a homogeneous suspension with a final concentration of 5 mg/ml.
Clear solution
5%DMSO 40%PEG300 5%Tween80 50%ddH2O

Validiert von Selleck Labs. Sollten Sie Anpassungen an dieser Formulierung benötigen, wenden Sie sich an unser Vertriebsteam für kundenspezifische Tests.

3.800mg/ml (9.99mM) Taking the 1 mL working solution as an example, add 50 μL of 76 mg/ml clarified DMSO stock solution to 400 μL of PEG300, mix evenly to clarify it; add 50 μL of Tween80 to the above system, mix evenly to clarify; then continue to add 500 μL of ddH2O to adjust the volume to 1 mL. The mixed solution should be used immediately for optimal results. 
Clear solution
5% DMSO 95% Corn oil

Validiert von Selleck Labs. Sollten Sie Anpassungen an dieser Formulierung benötigen, wenden Sie sich an unser Vertriebsteam für kundenspezifische Tests.

0.950mg/ml (2.50mM) Taking the 1 mL working solution as an example, add 50 μL of 19 mg/ml clear DMSO stock solution to 950 μL of corn oil and mix evenly. The mixed solution should be used immediately for optimal results. 
* <1 mg/ml bedeutet schwer löslich oder unlöslich.
* Bitte beachten Sie, dass Selleck die Löslichkeit aller Verbindungen intern testet und die tatsächliche Löslichkeit geringfügig von veröffentlichten Werten abweichen kann. Dies ist normal und ist auf geringfügige Batch-zu-Batch-Variationen zurückzuführen.
* Versand bei Raumtemperatur (Stabilitätstests zeigen, dass dieses Produkt ohne Kühlmaßnahmen versendet werden kann.)

Vorbereitung von Stammlösungen

Biologische Aktivität

Beschreibung GSK591 (EPZ015866, GSK3203591) ist ein potenter selektiver Inhibitor der Arginin-Methyltransferase PRMT5 mit einer IC50 von 4 nM.
Ziele
PRMT5
(Cell-free assay)
4 nM
In vitro

In einem biochemischen In-vitro-Assay hemmt GSK591 den PRMT5/MEP50-Komplex potent bei der Methylierung von (Histon) H4 mit einer IC50 = 11 nM. In Z-138-Zellen hemmt diese Verbindung die symmetrische Argininmethylierung von SmD3 mit einer EC50 = 56 nM. Des Weiteren ist diese Chemikalie selektiv für PRMT5 (bis zu 50 Mikromolar) im Vergleich zu einer Reihe von Methyltransferasen.

Protokoll (aus Referenz)

Tierstudie:

[4]

  • Tiermodelle

    BALB/C nude mice

  • Dosierungen

    50 mg/kg

  • Verabreichung

    s.c.

Referenzen

  • https://pubmed.ncbi.nlm.nih.gov/26985292/
  • https://pubmed.ncbi.nlm.nih.gov/25915199/
  • http://www.thesgc.org/chemical-probes/GSK591
  • https://pubmed.ncbi.nlm.nih.gov/35111150/

Kundenproduktvalidierung

Treatment of HCC cells with 500 nmol/L GSK591 for 4 days led to significant loss of PRMT5-catalyzed methylarginine on H4 (H4R3me2s), the upregulation of BTG2, and the phosphorylation of ERK. Inhibition of ERK phosphorylation by PD184352 treatment reversed these effects. H4R3me2s was used to detect the PRMT5 activity. Histone 3 was used as nuclear loading control.

Daten von [ , , Cancer Med, 2018, 7(3):869-882 ]

Sellecks GSK591 Wurde zitiert von 15 Publikationen

PRMT5 deficiency in myeloid cells reprograms macrophages to enhance antitumor immunity and synergizes with anti-PD-L1 therapy [ J Immunother Cancer, 2025, 13(4)e011299] PubMed: 40187753
PRMT5 mediated FUBP1 methylation accelerates prostate cancer progression [ J Clin Invest, 2024, e175023] PubMed: 39146021
Spliceosomal vulnerability of MYCN-amplified neuroblastoma is contingent on PRMT5-mediated regulation of epitranscriptomic and metabolomic pathways [ Cancer Lett, 2024, 604:217263] PubMed: 39313128
CD38 symmetric dimethyl site R58 promotes malignant tumor cell immune escape by regulating the cAMP-GSK3β-PD-L1 axis [ Heliyon, 2024, 10(19):e37958] PubMed: 39386836
Development and validation of a generic methyltransferase enzymatic assay based on an SAH riboswitch [ SLAS Discov, 2024, 29(4):100161] PubMed: 38788976
(S)-2-(Cyclobutylamino)-N-(3-(3,4-dihydroisoquinolin-2(1H)-yl)-2-hydroxypropyl)isonicotinamide Attenuates RANKL-Induced Osteoclast Differentiation by Inhibiting NF-κB Nuclear Translocation [ Int J Mol Sci, 2023, 24(5)4327] PubMed: 36901758
Global profiling of arginine dimethylation in regulating protein phase separation by a steric effect-based chemical-enrichment method [ Proc Natl Acad Sci U S A, 2022, 119(43):e2205255119] PubMed: 36256816
HBV covalently closed circular DNA minichromosomes in distinct epigenetic transcriptional states differ in their vulnerability to damage [ Hepatology, 2021, 10.1002/hep.32245] PubMed: 34779008
PRMT5 Inhibition Promotes PD-L1 Expression and Immuno-Resistance in Lung Cancer [ Front Immunol, 2021, 12:722188] PubMed: 35111150
An AKT/PRMT5/SREBP1 axis in lung adenocarcinoma regulates de novo lipogenesis and tumor growth [ Cancer Sci, 2021, 10.1111/cas.14988] PubMed: 34033176

RÜCKGABERICHTLINIE
Die bedingungslose Rückgaberichtlinie von Selleck Chemical gewährleistet unseren Kunden ein reibungsloses Online-Einkaufserlebnis. Wenn Sie in irgendeiner Weise mit Ihrem Kauf unzufrieden sind, können Sie jeden Artikel innerhalb von 7 Tagen nach Erhalt zurückgeben. Im Falle von Produktqualitätsproblemen, sei es protokollbezogene oder produktbezogene Probleme, können Sie jeden Artikel innerhalb von 365 Tagen ab dem ursprünglichen Kaufdatum zurückgeben. Bitte befolgen Sie die nachstehenden Anweisungen, wenn Sie Produkte zurücksenden.

VERSAND UND LAGERUNG
Selleck-Produkte werden bei Raumtemperatur transportiert. Wenn Sie das Produkt bei Raumtemperatur erhalten, seien Sie versichert, dass die Qualitätskontrollabteilung von Selleck Experimente durchgeführt hat, um zu überprüfen, dass die normale Temperaturplatzierung von einem Monat die biologische Aktivität von Pulverprodukten nicht beeinträchtigt. Nach dem Sammeln lagern Sie das Produkt bitte gemäß den in der Datenblatt beschriebenen Anforderungen. Die meisten Selleck-Produkte sind unter den empfohlenen Bedingungen stabil.

NICHT FÜR DIE ANWENDUNG AM MENSCHEN, FÜR VETERINÄRMEDIZINISCHE DIAGNOSTIK ODER THERAPEUTISCHE ZWECKE.